Installation and service instructions
for contractors
VIESMANN
Vitodens 222-F
Type B2TF, 1.9 to 32 kW
Gas condensing storage combi boiler with 7 inch colour touchscreen
Natural gas and LPG version
VITODENS 222-F
6151778 GB 5/2020
Please keep safe.

Table of Contents

Questions and Answers

  • C
    Christy HooverAug 28, 2025
    Why is my Viessmann B2TF Boiler showing fault code bb?
    • R
      richardcookAug 28, 2025
      If your Viessmann Boiler displays fault code bb, it indicates a communication error with the extension kit for heating circuit 3 (with mixer). Check extension kit connections and code.
  • N
    Nathan SandersAug 28, 2025
    How to fix fault code bC on Viessmann B2TF Boiler?
    • R
      Robin DelgadoAug 29, 2025
      If your Viessmann Boiler displays fault code bC, it indicates a communication error with the remote control Vitotrol heating circuit 1 (without mixer). Check connections, lead, coding address "A0" and remote control settings.
  • T
    Teresa SanchezSep 22, 2025
    What does error code Ed mean on a Viessmann B2TF Boiler?
    • Q
      qwilliamsSep 22, 2025
      If your Viessmann Boiler displays error code Ed, it indicates an internal fault. To resolve this, replace the control unit.
  • F
    floresaprilSep 23, 2025
    What does error code E5 mean on a Viessmann Boiler?
    • T
      Tina MccallSep 23, 2025
      If your Viessmann Boiler displays error code E5, it indicates a fault with the flame amplifier. To resolve this, replace the control unit.
  • D
    dale27Sep 23, 2025
    What does error code E4 mean on my Viessmann B2TF Boiler?
    • R
      Ryan FitzgeraldSep 23, 2025
      If your Viessmann Boiler displays error code E4, it indicates a fault in the supply voltage of 24 V. To resolve this, replace the control unit.
  • M
    Melissa BrewerSep 8, 2025
    What does Fault Code dA mean on my Viessmann B2TF Boiler?
    • E
      edwardmccarthySep 8, 2025
      If your Viessmann Boiler displays Fault Code dA, there is a short circuit in the room temperature sensor for heating circuit 1 (without mixer). Check the room temperature sensor for heating circuit 1.
  • O
    odiazAug 30, 2025
    What causes fault code C3 on a Viessmann B2TF?
    • D
      Debbie SandovalAug 30, 2025
      If your Viessmann Boiler displays fault code C3, it indicates an Extension AM1 communication error. Check electrical connections.
  • S
    Shannon MorrisAug 30, 2025
    How do I fix fault code C4 on my Viessmann Boiler?
    • J
      julieclarkeAug 30, 2025
      If your Viessmann Boiler displays fault code C4, it indicates a communication error with the Open Therm extension. Check Open Therm extension.
  • S
    Scott HawkinsAug 30, 2025
    What does fault code C5 mean on a Viessmann Boiler?
    • T
      Tammy WardAug 30, 2025
      If your Viessmann Boiler displays fault code C5, it indicates a communication error with the variable speed internal pump. Check the setting of coding address "30".
  • E
    Edward SmithAug 30, 2025
    What should I do if my Viessmann B2TF Boiler shows fault code C6?
    • C
      Christopher TaylorAug 30, 2025
      If your Viessmann Boiler displays fault code C6, it indicates a communication error with the external variable speed heating circuit pump, heating circuit 2 (with mixer). Check setting of coding address "E5".

Viessmann B2TF Specifications

General IconGeneral
BrandViessmann
ModelB2TF
CategoryBoiler
LanguageEnglish