Page 34 of 72 PYROMAT DYN45 - DYN85 Issue 1.0 5726 783
Heating system is
in operation
L Have the requisite amount of wood ready before opening the firebox door.
1. Press F1 "PYROMAT manual" button.
Danger of deflagration!
Low temperature gas in the upper area of the firebox can lead to deflagration.
Caution!
1. Lift the firebox door up slightly:
Any possible low temperature gas will be drawn off by the exhaust gas blower.
2. Open firebox door:
Release the firebox door lock and open the firebox door fully.
L With heating systems with storage as hydraulic switcher:
Only reduced heating operation possible, only fill firebox partially - depending on
heat take-off, max 20 to 40kg per filling.
L With heating systems with ECO function (optional), storage with storage control
valve:
Unrestricted heating operation possible - only fill in so much wood as the storage
can take energy from, until the maximum storage temperature of 90°C is reached.
Danger of deflagration!
Low temperature gas formation due to sawdust or fine wood chips.
Caution!
1. Under no circumstances feed sawdust or chopped wood pieces directly onto the grate.
3. Arrange split logs or wood pieces horizontally and compactly over the complete
width of the boiler in the firebox.
4. Remove any dirt that may exist on the contact surfaces of the firebox door.
5. Close firebox door.