Operating instructions
for the system user
VIESMANN
Heating system with Vitotronic 200 control unit, type HO2B/HO2C
For weather-compensated operation
VITODENS
VITOSOLAR 300-F
5811580 GB/en 8/2017
Please keep safe.

Table of Contents

Other manuals for Viessmann VITODENS

Questions and Answers

  • D
    donaldnewmanJul 26, 2025
    What to do if 'Fault' and 'E' are displayed on my Viessmann Heating System?
    • M
      Mackenzie PerkinsJul 26, 2025
      If your Viessmann Heating System displays 'Fault' and 'E', accompanied by a flashing red fault indicator, attempt to resolve the issue by pressing the burner fault reset button labeled "E". If the problem continues after resetting, it is recommended to contact your heating contractor for further assistance.
  • N
    nathanchangAug 1, 2025
    Why are my rooms too cold with my Viessmann Heating System?
    • E
      Erika RodgersAug 1, 2025
      If the rooms are too cold, several factors could be at play. First, ensure the heating system is switched ON; the ON indicator "8" should be green. Also, check the main isolator (if installed) and the circuit breaker inside the power distribution board. If a 'Fault' and 'E' are displayed with a flashing red fault indicator, press the burner fault reset button "E"; if the issue persists, contact your heating contractor. If that doesn't work, check the fuel level or gas supply, opening the gas shut-off valve if necessary, and then press burner fault reset "E".
  • C
    Carlos JohnsonAug 7, 2025
    What to do if my Viessmann Heating System is prioritizing DHW and the rooms are too cold?
    • M
      Mark MontgomeryAug 7, 2025
      If the rooms are too cold, and you are operating with DHW heating, it might be due to DHW priority (indicated by 'wp' on the display). In this case, wait until the DHW cylinder has been fully heated. If you're using an instantaneous water heater, wait until no more DHW is being drawn off (indicated by 'p' disappearing from the display).
  • C
    Christopher AndrewsAug 13, 2025
    Why are my rooms too cold when using Vitotronic 200-H with my Viessmann Heating System?
    • J
      jessicasmithAug 13, 2025
      If the rooms are too cold, and you have a Vitotronic 200-H or extension kit with a mixer, check the ON/OFF switch on the mixer motor. Ensure it is switched ON; the correct setting is I = ON.
  • A
    Anthony BarnesAug 20, 2025
    Why is my Viessmann Heating System not providing heat due to lack of fuel?
    • W
      wardsaraAug 20, 2025
      If the rooms are too cold, the problem could be a lack of fuel. For oil/LPG systems, check the fuel stock and re-order if necessary. For natural gas systems, open the gas shut-off valve and consult your gas supplier if needed. After addressing the fuel supply, press the burner fault reset button "E".

Summary

Safety Instructions

General Safety Advice

Follow safety instructions to prevent accidents and material losses.

Emergency Procedures

Steps to take during gas leaks, fire, water leaks, or system faults.

Operation

Operating Programs

Selecting predefined operational modes.

Time Programs

Setting heating schedules and time phases.

Start-up and Shutdown

Starting Up the Heating System

Procedures for initial system activation.

Shutting Down the Heating System

Procedures for safe system deactivation.

Central Heating

Room Temperature Settings

Adjusting desired room temperatures.

Operating Program for Heating

Setting heating operational modes.

Time Program for Heating

Scheduling heating periods.

DHW Heating

DHW Temperature Settings

Adjusting domestic hot water temperature.

Operating Program for DHW

Selecting DHW heating modes.

Time Program for DHW

Scheduling domestic hot water heating.

Mechanical Ventilation

Calling Up Information

Fault and Service Message Scanning

Diagnosing system errors and alerts.

What To Do If... (Troubleshooting)

Rooms Too Cold

Diagnosing and resolving temperature issues.

Rooms Too Hot

Diagnosing and resolving temperature issues.

No Hot Water

Troubleshooting hot water supply problems.

DHW Too Hot

Troubleshooting hot water supply problems.

Fault Messages and Indicators

Interpreting and responding to system faults.

Maintenance

Viessmann VITODENS Specifications

General IconGeneral
TypeCondensing Boiler
Heat Exchanger MaterialStainless Steel
Fuel TypeNatural gas, LPG
EfficiencyUp to 98%
Modulation Ratio1:10
Control SystemVitotronic
MountingWall-mounted
WarrantyUp to 10 years (depending on model and conditions)