15
Operating programs for central heating, DHW, frost protection
Note
DHW heating is only shown if your boiler is equip-
ped with a DHW heating function.
Symbol Operating program Function
Central heating and DHW heating
"Heating and DHW"
The rooms of the selected heating circuit are
heated in accordance with the room temperature
and time program specified (see chapter "Central
heating").
DHW is heated in accordance with the DHW
temperature and time program specified (see
chapter "DHW heating").
DHW heating
"Only DHW"
DHW is heated in accordance with the DHW
temperature and time program specified (see
chapter "DHW heating").
No central heating
Frost protection for the boiler and the DHW cylin-
der is enabled.
Frost protection
"Standby mode"
No central heating
No DHW heating
Frost protection for the boiler and the DHW cylin-
der is enabled.
Operating programs for ventilation
Operating program Operating status Air flow rate Ventilation
level
"Standby mode" No ventilation 0
"Basic mode" Minimum air flow rate 1
"Automatic mode" "Reduced" Reduced air flow rate
Approx. 70 % of the nominal air flow
rate; see operating status "Normal"
2
"Normal" Standard air flow rate
If a humidity and/or CO
2
sensor is in-
stalled in your home, the air flow rate
is adjusted subject to the humidity
and/or CO
2
concentration.
3
"Intensive operation" Maximum air flow rate
Approx. 125 % of the nominal air flow
rate; see operating status "Normal"
4
Note
The respective air flow rates for "Reduced", "Normal"
and "Intensive operation" are set by your heating
contractor.
Operation
Operating program
5811580