116
Danger
There is a risk of electric shock from escaping
heating water or DHW.
When commissioning and after carrying out
maintenance work, check all water side connec-
tions for leaks.
!
Please note
Leaking hydraulic connections lead to appliance
damage.
■
Check the internal and on-site hydraulic con-
nections for leaks.
■
In the event of leaks, switch off the appliance
immediately. Drain the heating water. Check
the seating of seal rings. Always replace dis-
placed seal rings.
Releasing the outdoor unit transport bracket
!
Please note
Premature loosening of the transport bracket
may cause damage to the outdoor unit.
■
Only release the transport lock once the sys-
tem has been completely filled and vented.
■
Re-engage the transport lock before topping
up heating water.
Fig. 80
To release the transport bracket securing screw
A
with an Allen key (size 5), turning it fully to the right.
Commissioning, inspection, maintenance
Checking all connections on the heating water and DHW sides for leaks
6222080