199
Type AWOT-M-E-AC/
AWOT-M-E-AC-AF
251.A 04 SP
04 2C SP
06 SP
06 2C SP
08 SP
08 2C SP
10 SP
10 2C SP
13 SP
13 2C SP
Mobile data transfer
WiFi
Transfer standard IEEE 802.11 b/g/n
Frequency band MHz 2400 to 2483.5
Max. transmission power dBm +15
Low power radio
Transfer standard IEEE 802.15.4
Frequency band MHz 2400 to 2483.5
Max. transmission power dBm +6
Service link
Transfer standard LTE-CAT-NB1
Frequency band 3 MHz 1710 to 1785
Frequency band 8 MHz 880 to 915
Frequency band 20 MHz 832 to 862
Max. transmission power dBm +23
Refrigerant circuit
Refrigerant R290 R290 R290 R290 R290
Safety group A3 A3 A3 A3 A3
Charge weight kg 1.2 1.2 1.2 2 2
Global warming potential (GWP)
*3
0.02 0.02 0.02 0.02 0.02
CO
2
equivalent t 0.000024 0.000024 0.000024 0.00004 0.00004
Compressor (hermetically sealed) Type Twin rotary
Oil in compressor Type HAF68 HAF68 HAF68 HAF68 HAF68
Oil volume in compressor l 0.840
±0.020
0.840
±0.020
0.840
±0.020
1.150
±0.020
1.150
±0.020
Permissible operating pressure
High pressure side bar 30.3 30.3 30.3 30.3 30.3
MPa 3.03 3.03 3.03 3.03 3.03
Low pressure side bar 30.3 30.3 30.3 30.3 30.3
MPa 3.03 3.03 3.03 3.03 3.03
Integral DHW cylinder
Capacity l 190 190 190 190 190
Max. draw-off volume at mixed wa-
ter temperature 40 °C (V40)
l 260 260 260 260 260
Reference DHW temperature θ'WH °C 53.5 53.7 53.7 52.1 52.1
Max. permissible DHW temperature °C 70 70 70 70 70
Outdoor unit dimensions
Total length mm 600 600 600 600 600
Total width mm 1144 1144 1144 1144 1144
Total height mm 841 841 841 1382 1382
*3
Based on the Sixth Assessment Report of the Intergovernmental Panel on Climate Change (IPCC AR6)
Specification
Specification (cont.)
6222080
Appendix