Fitting the thermometer sensor (if applicable)
7.
2.
4.
5.
6.
3.
1.
Fig. 13
1. Guide the thermometer sensor through the cover
strip and insert the thermometer.
2. Guide the upper thermometer sensor through the
lifting eye, insert it into the clamping bracket as far
as possible and tighten the wing nut.
Note
The cover strip is held in its vertical position by the
straight capillaries. This is necessary for the rest of
the installation.
3. Route the thermometer sensor capillaries to the
back.
Note
Repeat the following steps for each of the thermom-
eters installed.
4. Depending on where the thermometer sensor is to
be fitted, secure it in the clamping bracket or pull
the sensor retainer out of the sensor well.
5. Secure the sensor to the outside of the sensor
retainer contact spring so that it is flush with the
front of the spring.
Note
Never wrap insulating tape around the thermometer
sensor.
6. Secure the thermometer sensor capillaries.
7. Insert the sensor retainer.