Operating instructions
for the system user
VIESMANN
Heating system with the Vitotronic 200 control unit, type HO1B, for
weather-compensated mode
VITODENS
VITOLADENS
VITOPEND
5592 682 GB 10/2013
Please keep safe.

Questions and Answers

  • C
    Courtney ScottJul 27, 2025
    What to do if 'Fault' and 'E' are displayed on my Viessmann Heating System?
    • M
      Mrs. Linda LucasJul 27, 2025
      If your Viessmann Heating System displays 'Fault' and 'E', accompanied by a flashing red fault indicator, attempt to resolve the issue by pressing the burner fault reset button labeled "E". If the problem continues after resetting, it is recommended to contact your heating contractor for further assistance.
  • W
    Whitney CummingsAug 2, 2025
    Why are my rooms too cold with my Viessmann VITOPEND?
    • K
      Kelly HardyAug 2, 2025
      If the rooms are too cold, several factors could be at play. First, ensure the heating system is switched ON; the ON indicator "8" should be green. Also, check the main isolator (if installed) and the circuit breaker inside the power distribution board. If a 'Fault' and 'E' are displayed with a flashing red fault indicator, press the burner fault reset button "E"; if the issue persists, contact your heating contractor. If that doesn't work, check the fuel level or gas supply, opening the gas shut-off valve if necessary, and then press burner fault reset "E".
  • C
    Charles WebbAug 8, 2025
    What to do if my Viessmann VITOPEND Heating System is prioritizing DHW and the rooms are too cold?
    • J
      Jordan LaneAug 8, 2025
      If the rooms are too cold, and you are operating with DHW heating, it might be due to DHW priority (indicated by 'wp' on the display). In this case, wait until the DHW cylinder has been fully heated. If you're using an instantaneous water heater, wait until no more DHW is being drawn off (indicated by 'p' disappearing from the display).
  • S
    Sara ClarkeAug 14, 2025
    Why are my rooms too cold when using Vitotronic 200-H with my Viessmann VITOPEND?
    • M
      miguel57Aug 14, 2025
      If the rooms are too cold, and you have a Vitotronic 200-H or extension kit with a mixer, check the ON/OFF switch on the mixer motor. Ensure it is switched ON; the correct setting is I = ON.
  • A
    alan55Aug 20, 2025
    Why is my Viessmann Heating System not providing heat due to lack of fuel?
    • J
      Jessica TorresAug 20, 2025
      If the rooms are too cold, the problem could be a lack of fuel. For oil/LPG systems, check the fuel stock and re-order if necessary. For natural gas systems, open the gas shut-off valve and consult your gas supplier if needed. After addressing the fuel supply, press the burner fault reset button "E".

Summary

Safety Instructions

General Safety Precautions

Covers general safety, symbol explanations, and target group for safe appliance operation.

Specific Safety Warnings

Addresses flue gas, fire, installation room conditions, and fault handling for hazard prevention.

Component and Operational Safety

Discusses extractors, auxiliary components, and spare parts to ensure safe system functioning.

Operation and Control

Navigating the Control Unit

Explains how to open, interact with the control unit interface, buttons, and screensaver.

Menu System Overview

Introduces standard, extended menus, help functions, and system symbols for operation.

Operating Programs and Time Scheduling

Explains operating programs, setting time programs, and comfort modes like Party, Economy, Holiday.

System Management: Start-up, Shutdown, and Heating

Start-up and Shutdown Procedures

Details steps for starting, stopping the system, and essential operational precautions.

Central Heating Configuration

Guides on setting room temperatures, operating programs, and adjusting the heating curve.

DHW Heating Control

Instructions for DHW temperature, operating programs, time programs, and stopping DHW heating.

System Adjustments and Diagnostics

Display and Circuit Settings

Covers adjusting display contrast, brightness, and naming heating circuits.

System Configuration Management

Details on setting time/date, language, temperature units, and restoring factory settings.

Scanning and Fault Diagnosis

Instructions for viewing system information, handling service/fault messages, and emissions tests.

Maintenance, Fuel, and Appendix

Repair and Maintenance Procedures

Outlines cleaning, inspection, and maintenance for system components like boiler and DHW cylinder.

Fuel Oil Requirements and Biofuels

Specifies fuel oil quality, additives, combustion improvers, and biofuel compliance.

Appendix: Menu Structure and Terminology

Provides an overview of the extended menu, information categories, and detailed system terminology.

Viessmann VITOPEND Specifications

General IconGeneral
TypeCondensing Boiler
MountingWall-mounted
Max flow temperature85 °C
Fuel TypeNatural Gas / Propane
EfficiencyUp to 98%
Water pressureMax. 3 bar
Protection classIPX4