Operating programs for central heating, DHW, frost protection
Symbol Operating program Function
Central heating and DHW heating
"Heating and DHW" The rooms of the selected heating
circuit are heated in accordance
with the room temperature and time
program specified (see chapter
"Central heating").
DHW is heated in accordance with
the DHW temperature and time pro-
gram specified (see chapter "DHW
heating").
DHW heating
"Only DHW" DHW is heated in accordance with
the DHW temperature and time pro-
gram specified (see chapter "DHW
heating").
No central heating
Frost protection is active.
Frost protection
"Standby mode" No central heating
No DHW heating
Frost protection for the boiler and
the DHW cylinder is active.
Special operating programs
Display in the standard menu
40°CBoiler temperature
HC1
14°C
21°C
Screed drying
F
Special operating programs F:
"Screed drying"
This function is activated by your heat-
ing contractor. Your screed is dried in
line with a set time program suitable
for the building material (tempera-
ture:time profile). Your settings for
central heating have no effect for the
duration of the screed drying.
"External hook-up"
Your heat pump control unit is regula-
ted by a higher control unit.
Operation