45
Cause Remedy
The heating system is switched off. Turn on the ON/OFF switch (see dia-
grams from page 22).
Switch on the mains isolator if installed
(outside the boiler room).
Reset the MCB in the power distribution
board (main domestic MCB).
Control unit incorrectly adjusted.
The remote control (if installed) is set
incorrectly.
Separate operating instructions
Central heating must be enabled.
Check settings and correct if required:
Operating program (see page 25)
Room temperature (see page 25)
Time (see page 36)
Central heating time program (see
page 25)
Heating curve (see page 26)
The DHW cylinder is heated. Wait until the DHW cylinder has been
heated up.
Reduce the DHW draw-off rate or tempo-
rarily reduce the standard DHW temper-
ature as required.
Note
In the case of operation with an instanta-
neous water heater, stop DHW draw-off.
No fuel. With oil/LPG:
Check the fuel reserves and re-order if
required.
With natural gas:
Open the gas shut-off valve. If necessary,
check with your gas supply utility.
What to do if...
Rooms are too cold
5592 682 GB

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Viessmann VITOPEND and is the answer not in the manual?

Viessmann VITOPEND Specifications

General IconGeneral
TypeCondensing Boiler
MountingWall-mounted
Max flow temperature85 °C
Fuel TypeNatural Gas / Propane
EfficiencyUp to 98%
Water pressureMax. 3 bar
Protection classIPX4

Related product manuals