101
Function Code Operat-
ing level
Setting options Delivered
condition
"Flow temp setpoint
screed drying"
1455 "F2" 0 to 95 °C 0
"Screed drying day" 1456 "F2" 0 to 32 days 0
"Floor curing days com-
pleted"
1457 "F2" 0 to 32 days 0
"Heating circuit 3 with
buffer"
The heating circuit is con-
nected to a heating water
buffer cylinder.
1470 "F2" ■ "No"
■ "Yes"
"Yes"
"Heating circuit 3 with
prim contr/system
pump"
Connecting line to the
heating circuit with/without
upstream control equip-
ment or feed pump.
1472 "F2" ■ "No"
■ "Yes"
"Yes"
"Optg mode change-
over"
1500 "F2" ■ "None"
■ "Frost protec-
tion mode"
■ "Reduced"
■ "Comfort"
■ "Automatic"
"None"
"DHW"
Function Code Operat-
ing level
Setting options Delivered
condition
"Nominal setpoint DHW" 1610 "E" 8 to 68 °C 60
"DHW temperature re-
duced setpoint"
1612 "E" 8 to 68 °C 40
"DHW release" 1620 "F2" ■ "24 h/day"
■ "Time pro-
grams with ad-
vance"
■ "Time pro-
gram 4"
"Time pro-
grams with
advance"
Codes
Changing codes
(cont.)
5618 294 GB
Service