1. Switch OFF the main power supply
and the ON/OFF switch at the control
unit.
2. Close the gas shut-off valve and safe-
guard against reopening.
3.
Undo re-usable cable ties A at the
gas/air duct of the auxiliary burner.
4. Pull cables from ignition electrode
B
and ionisation electrode
C
as
well as the earth cable.
5. Undo the union nut on gas/air duct
D
.
6. Undo four screws from the burner
cover and remove burner
E
.
!
Please note
If the wire gauze is damaged,
this can affect the burner func-
tion.
Never rest the burner on the
gauze assembly.
Checking the burner gasket and burner gauze assembly
Check burner gasket A and burner
gauze assembly
E
for possible damage
and replace if required.
Commissioning, inspection, maintenance