77
Checking the condensate drain and cleaning the siphon
A
1. Check at the siphon that the conden-
sate can drain freely.
2. Remove and clean (flush) siphon
A
.
3.
Fill siphon A with water via the inlet
port and reinstall.
Check the length of the Stirling engine damping springs
Note
The spring length only needs to be
checked and adjusted when Stirling
engine, cooled plate, Omega gasket or
springs are replaced.
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)