87
Function Code Operat-
ing level
Setting options Delivered
condition
"Direct adjustment"
Automatically save: A
code change (via the ro-
tary selector) is accep-
ted both by pressing
"OK", and without con-
firming (time out).
Storage with confirma-
tion: A code change (via
the rotary selector) is on-
ly accepted by pressing
"OK".
28 "F1" "Automatic
storage"
"Storage with
confirmation"
"Storage
with confir-
mation"
A remote control unit and its effects on the heating circuits is assigned by the fol-
lowing coding addresses. Coding addresses 40, 42, 47 and 54 are only displayed
on the remote control unit.
"Device address"
See separate remote con-
trol unit documents.
40 "F1" "Room unit 1"
"Room unit 2"
"Room unit 3/
P"
"Operator unit
1"
"Operator unit
2"
"Operator unit
3/P"
"Service unit"
- - -
"Assignment device 1" 42 "F1" "Heating cir-
cuit 1"
"Heating cir-
cuits 1 and 2"
"Heating cir-
cuits 1 and 3/
P"
"All heating
circuits"
"Heating cir-
cuit 1"
"Operation HC2" 44 "F1" "Jointly with
HC1"
"Independent-
ly"
"Jointly with
HC1"
Codes
Changing codes
(cont.)
5618 294 GB
Service