 Length ID Command Command Response
Range
Comments
Type (ASCII) Code
(ASCII)
Code
(Hex)
(Three ASCII
bytes)
Get-Brightness 8 g b 62 000 ~ 100
Get-Backlight
*3.2.0
8 a B 42 000 ~ 100 1. For Android
platform whose main
mode is controlled
by backlight and the
other sources are
controlled by bright-
ness.
2. Derived from Color
calibration.
*3.2.0
Get-Volume 8 g f 66 000 ~ 100
Get-Mute 8 g g 67 000: Off
001: On (muted)
Get-Input select 8 g j 6A 000~
100~
1. 1st digit for signal
detection: 0 means
“no signal”; 1
means “signal
detected”
2. 2nd &3rd digit: See
Set-function table
Get-Power status:
ON/ STBY
8 g l 6C 001: ON
000: STBY
Get-Remote control S g n 6E 000: Disable
001: Enable
002: Pass through
Get RCU mode status
Get-Power lock 8 g o 6F 000: Unlock
001: Lock
Get-Button lock 8 g p 70 000: Unlock
001: Lock
Get-Menu lock 8 g l 6C 000: Unlock
001: Lock
Get-ACK 8 g z 7A 000 This command is
used to test the com-
munication link
Get-Thermal 8 g 0 30 000~100:
0~+100 deg C
-01~-99:
-1~-99 deg C
Get-Operation
time
*3.2.0
8 g 1 31 000 1. Accumulated
hours in 6-digit
integer (000,001~
999,999)*3.2.0
2. Can not be reset
when FW update and
Factory initiation*3.2.2
3. Reply in new 32-
byte format*3.2.0
Get-Device name 8 g 4 34 000 Reply in new 32-byte
format *3.2.0

Table of Contents

Other manuals for ViewSonic IFP30 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ViewSonic IFP30 Series and is the answer not in the manual?

ViewSonic IFP30 Series Specifications

General IconGeneral
BrandViewSonic
ModelIFP30 Series
CategoryMonitor
LanguageEnglish

Related product manuals