LED References
In addition to the LCD Display, the control board LEDs monitor the various circuits of the
control board. Use the table below to identify the corresponding “TS Ref#” and refer to
page 38-41 for further troubleshooting.
TROUBLESHOOTING
# LED Status Meaning
Page 41
TS Ref#(s)
1 “Magnetic
Lock Relay”
OFF At Closed Limit and Magnetic Lock Relay state is closed across “COM” &
“N.C.”. Gate should be at the Close Limit.
SOLID Not at Closed Limit and Magnetic Lock Relay state is closed across “COM” &
“N.O.”. Gate should not be at the Close Limit
2 “Check Motor” OFF Normal Condition.
SOLID The control board is sending power to the motor but the circuit is open.
7, 8
3 “Battery Low” OFF Normal Condition.
SOLID Does not apply to Solar Units.
FLASHING Batteries critically low. Check power supply to the operator (pg 20).
4 “POWER” OFF No power to control board (pg 20) or board is in sleep mode.
5
SOLID Normal Condition.
5 “Radio” OFF Normal Condition.
SOLID Control Board is receiving an input from a device connected to the
Radio terminal (pg 30, 42).
9, 10
6 “UL” OFF Normal Condition.
SOLID Control Board is receiving an input from a device connected to the UL
terminal or when more than one device is connected (pg 10-11, 28, 42).
9, 10, 16,
22
7 “Re-Open” OFF Normal Condition.
SOLID Control Board is receiving an input from a device connected to the Re-
Open terminal or when more than one device is connected (pg 10-11, 29,
32, 42).
9, 10, 16,
22
8 “ATG” OFF Normal Condition.
SOLID Control Board is receiving an input from a device connected to the ATG
terminal (pg 31, 42).
9, 10