Manual BG41/BG42/BG43 Software
Rev. 99/49 4-11
Examples: FB100 (PROCW)
It should be operated without a protocol or a procedure through channel 1 of the building block. The
building block’s base address is F0A0. Any error which may possibly arise, should be filed in the
flag byte MB 127.
SPA FB100
NAME :PROCW
ADR :KH F0A0 Building block’s absolute base address
KANR :KF+1 Channel 1
PROC :KF+0 Code for without protocol/procedure
FEHL :MB127 Error code in flag byte 127
Procedure STX/ETX should be used through channel 3 of the building block. The building block’s
base address is F0A0. Any errors which may possibly occur, should be filed in the flag byte MB
107.
SPA FB100
NAME :PROCW
ADR :KH F0A0 Building block’s absolute base address
KANR :KF+3 Channel 3
PROC :KF+1 Code for procedure STX/ETX
FEHL :MB127 Error code in flag byte 127