Presetting Manual BG41/BG42/BG43
5-10 Rev. 99/49
5.2.8 Plug connectors J6, J11 and J12
Plug connector J6
With the plug connector J6 the voltage supply is switched
(internally via X1 and X2, externally via the 25-pole SubD socket(s)).
In the position shown here, the plug connector is in the parking position
(state at delivery).
Plug connector J11
With the plug connector J11 the area of the eligible baud rate is set.
In this setting the baud rates of 150 baud to 38.400 baud are possible.
In this setting (state at delivery) the baud rates of 75 baud to 19.200 baud
are possible.
Plug connector J12
With the plug connector J12 the battery’s floating charge is set, which is
necessary for particular applications.
The building blocks and modules described in this handbook do not
require a float charging of the battery. Leave J12 plugged into the position
shown (state at delivery).