Application of interfaces without data handling blocks Manual BG41/BG42/BG43
4-92 Rev. 99/49
4.2.5.3 Change the channel’s baud rate
Command 2
This command is a two-byte command and requires the transfer of the code for the baud rate into
the second byte.
If a baud rate of 38400 baud is used, the plug connector J11 on the base
circuit board is to be placed in position 38.4.
Assignment list (code/baud rate)
Fig. 4-22: Code/baud rate
Example 1:
Channel 1 should be set to 4800 baud.
J11 is plugged into position 19200
Fig. 4-23: Example 1, changing the baud rate