Manual BG41/BG42/BG43 Startup
Rev. 99/49 5-23
Power On OB
OB22
BIB #5095
00000 :
00002 :SPA FB 100
NAME #PROCW
ADR =KH F080 Base address
KANR =KF +1 Interface number
PROC =KF +1 Procedure STX/ETX
FEHL =MB 199 Error byte
0000E :
00010 :SPA FB 40
NAME #PARA-STX
ADR =KH F080 Base address
K/M =KY 1,1 Interface 1/with FIFO
STX =KY 0,2 Start classification is 02H
E1/2 =KY 3,4 End classification is 03H04H
ZVZ =KF +50 2500ms(Value * 50ms)
FEHL =MB 198 Error byte
00020 :
00022 :SPA FB 100
NAME #PROCW
ADR =KH F080 Base address
KANR =KF +2 Interface number
PROC =KF +1 Procedure STX/ETX
FEHL =MB 199 Error byte
0002E :
00030 :SPA FB 40
NAME #PARA-STX
ADR =KH F080 Base address
K/M =KY 2,0 Interface 2/ without FIFO
STX =KY 0,2 Start classification is 02H
E1/2 =KY 3,4 End classification is 03H04H
ZVZ =KF +50 2500ms(Value * 50ms)
FEHL =MB 198 Error byte
00040 :
00042 :UN M 1.0 Set new start flag
00044 :S M 1.0
00046 :BE