Manual BG41/BG42/BG43 Interface modules
Rev. 99/49 3-43
#OB21
00002 :SPA FB 100
NAME #PROCW
ADR =KH F080 Base address
KANR =KF +1 Channel number
PROC =KF +5 Procedure counter
FEHL =MB 199 Erorr byte
00010 :SPA FB 12
NAME #MODE
ADR =KH F080 Base address
KNR =KF +1 Channel number
MOD1 =KF +1 Counter 1 in mode 1
MOD2 =KF +3 Counter 2 in mode 3
MOD3 =KF +0 Counter 3 in mode 0
00020 :BE
#OB22
00002 :SPA FB 100
NAME #PROCW
ADR =KH F080 Base address
KANR =KF +1 Channel number
PROC =KF +5 Procedure counter
FEHL =MB 199 Error byte
00010 :SPA FB 12
NAME #MODE
ADR =KH F080 Base address
KNR =KF +1 Channel number
MOD1 =KF +1 Counter 1 in mode 1
MOD2 =KF +3 Counter 2 in mode 3
MOD3 =KF +0 Counter 3 in mode 0
00020 :BE
Cycle OB
#OB1
00002 :SPA FB 10 Read counter value
NAME #LESEN
ADR =KH F080 Base address
KNR =KF +1 Channel number
ZNR =KF +1 Counter number 1
WERT =MW 20 File count value in MW 20
NEUS =M 0.0 Power on flag
00012 :A DB 10
00014 :SPA FB 10 Read counter value
NAME #LESEN
ADR =KH F080 Base address
KNR =KF +1 Channel number
ZNR =KF +1 Counter number 1
WERT =DW 1 File count value in DW 1 DB 10
NEUS =M 0.0 Power on flag
00024 :A DB 10
00026 :U M 1.0 Flag to preset counter
00028 :R M 1.0
0002A :SPB FB 11 Preset counter
NAME #SCHREIBE
ADR =KH F080 Base address
KNR =KF +1 Channel number
ZNR =KF +2 Counter number 2
WERT =DW 2 Value is in DW 2 DB 10
NEUS =M 0.0 Power on flag
0003A :BE