13
3.7.2 LightWise™ Technology
VIQUA’s new LightWise™ technology allows the system’s electronic controller to
automatically reduce lamp power during periods of no water flow. The dimming
capability ultimately reduces the rate of sleeve fouling.
Benefits
• Lower maintenance; up to 60% less maintenance.
• Lower energy consumption; estimated savings of 30%.
• Lower operating temperature; maintained below 40°C in typical no flow conditions.
• Increased electrical efficiency minimizes carbon footprint.
40
45
50
55
60
65
70
75
80
85
0 10 20 30 40 50 60 70 80 90 100
%UVT
Real Time Dose UV System
Normal operation
System alarm
0
50
100
0 1 2 3 4 5
Relative Power (%)
Time (min)
Power Level
No Flow
No Flow
Flow