i
Table of Contents
Preface .............................................................................................................................ii
Contact Information ......................................................................................................ii
About VIQUA – a Trojan Technologies Business .........................................................ii
Scope ...........................................................................................................................ii
1.0 Project & System Description ................................................................................ 1
1.1 Project Description ............................................................................................. 1
1.2 System Description ............................................................................................ 1
2.0 Product Drawings .................................................................................................. 2
2.1 Install Diagram ................................................................................................... 2
2.2 Exploded View ................................................................................................... 3
3.0 System Overview .................................................................................................. 5
3.1 Pressure Drop .................................................................................................... 5
3.2 Dose Curves ...................................................................................................... 5
3.3 Controller Interface ............................................................................................. 7
3.4 UV Lamp ............................................................................................................ 8
3.4.1 Mercury Discharge Lamp Spectral Output ................................................... 8
3.4.2 Degradation Chart ....................................................................................... 9
3.4.3 Temperature Profile ..................................................................................... 9
3.4.4 Quartz Sleeve ............................................................................................ 11
3.5 UV Sensor ........................................................................................................ 11
3.5.1 Sensor Response Curve............................................................................ 11
3.6 Flowmeter ........................................................................................................ 12
3.7 Product Features and Benefits ......................................................................... 12
3.7.1 Real-Time UV Dose Monitoring ................................................................. 12
3.7.2 LightWise™ Technology ............................................................................ 13
3.7.3 Adjustable Alarm Set Points ...................................................................... 14
3.8 Signals and Remote Capabilities ..................................................................... 14
3.8.1 COMMcenter™ .......................................................................................... 14
3.8.2 Dry Contacts .............................................................................................. 14
3.8.3 4-20 mA Interface ...................................................................................... 15
4.0 Certifications ........................................................................................................ 15
5.0 Warranty .............................................................................................................. 15
VIQUA Declaration ........................................................................................................ 17