8. Periodic Test by User Code
D-304269 KP-250 PG2 User’s Guide 51
is currently being tested.
First the panel siren sounds for 3 seconds after which the PowerMaster system will
automatically repeat the procedure for the next siren enrolled in the system until all
sirens are tested.
5
You should listen to the sirens sounds and make sure that all sirens sound.
Once all the sirens have been tested, the control panel will now test the sirens of
smoke sensors that are enrolled in the alarm system. The display now reads [Zxx:
SMOKE SIREN] on the first line, and [<NEXT or <OK>] on the second line, where
"Zxx" indicates the zone number of the smoke sensor. During this time, the siren of
the tested smoke sensor will sound for up to one minute.
Press to test the siren of the next smoke sensor.
6.
SIREN TEST ENDED
When all the sirens test is complete, the display reads [SIREN TEST ENDED].
Press the or the button to confirm the test and then move to the next
step for zone temperature display.
or
C. To Display the Temperature
7.
TEMPERATURE TEST
The display now reads [TEMPERATURE TEST].
8.
To display the temperature of zones on the KP-250 PG2, press .
6
Z01 +19.5C
Z01:Temp. Sensor
The KP-250 PG2 reads the temperature of each zone. The display alternates
between the temperature, the sensor number and the sensor location.
7
Repeatedly click the button to review the temperature of each zone (by
Temperature Sensor).
Z01 +19.5C
Living room
9.
DEVICE TESTS END
When the temperature of all zones has been reviewed, the display reads
[DEVICE TESTS END]. Press the or the button to confirm the test
and then move to the next step to test the other devices.
or
D. To Test all other Devices
TEST ALL DEVICES
The display now reads [TEST ALL DEVICES].
10.
To enter the devices test procedure, press .
11.
NOT ACTIVE NNN
The display reads [NOT ACTIVE NNN]. NNN indicates the number of enrolled
devices in the panel that have not been tested yet. This number automatically
drops one count for every tested device. To initiate devices test, press .
Z01 NOT ACTIVE The display shows the 1
st