EasyManua.ls Logo

Visonic KP-250 PG2 - User Codes and Access Control

Visonic KP-250 PG2
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6. System Configuration
D-304269 KP-250 PG2 User’s Guide 25
5
a. If the zone you selected is "not bypassed", the display prompts you to press [
<OK> TO BYPASS
]. However, if
the zone you selected is already "bypassed", the display prompts you to press [
<OFF> TO CLEAR
].
b. To abort and return to the previous step press or
6
This menu is not displayed if Partition is enabled.
7
The display now prompts you to press [
<OK> TO RECALL
] i.e. to repeat the last used bypass scheme. To abort
and return to the User Settings menu, press
.
8
You can now repeat steps 2 - 4 to bypass or clear another zone. To end this session and to select other menu
options or to quit programming - follow the instructions in section A.2.
9
You can now select another option in the User Settings menu (see section A.1), or quit programming (see section
A.2).
B.4 Programming User Codes
PowerMaster system allows you to authorize up to 8 (PowerMaster-10 G2) / 48 (PowerMaster-30 G2 / PowerMaster-33
G2) people to arm and disarm the system by providing each with a unique 4 digit personal security code (code 0000 is
not allowed), and assigning them with different security levels and functionalities. Moreover, you can obtain up to 8
(PowerMaster-10 G2) / 32 (PowerMaster-30 G2 / PowerMaster-33 G2) multi-function portable keyfob transmitters that
will allow you and the other users to easily arm, disarm and control the system without accessing the KP-250 PG2 or
panel, including from outside the premises (see section B.7 Add / Delete Keyfob Transmitters). The Duress Code
enables you to disarm the system using a special code that sends a silent alarm to the monitoring station.
There are two types of users: Master User and User. The table below summarizes the different operations that can be
performed by different users:
User type Function
Master User
Arm/disarm
Zone bypass
Authorize other user codes
Set user codes
Report to private
Enroll/delete proximity tag
Enroll/delete keyfob
Automatic arming
Enable squawk
Set date and time format
Read event log
Programming the duress code
Programming the scheduler
Enabling/disabling voice option
Adjusting volume
User
Arm/disarm
Zone bypass options
The user codes are assigned as follows:
User Code 1 is assigned to the Master User of the system (i.e. the owner). It is the only user code that allows access to
the User Settings menu. The default setting of the Master User code is 1111. This code cannot be erased and must be
replaced with a secret code as soon as possible.
User Codes 2-4 (PowerMaster-10 G2) / User Codes 2-22 and 33-48 (PowerMaster-30 G2 / PowerMaster-33 G2) are
assigned to family members, co-workers etc. They enable arming and disarming of the system or of selected partitions
as defined by the Master User. They can access the "User Settings" menu only for "zone bypassing" provided this
option is enabled in the Installer menu.

Table of Contents

Other manuals for Visonic KP-250 PG2

Related product manuals