6. System Configuration 
D-304269 KP-250 PG2 User’s Guide  25 
5 
a.  If the zone you selected is "not bypassed", the display prompts you to press [
<OK> TO BYPASS
]. However, if 
the zone you selected is already "bypassed", the display prompts you to press [
<OFF> TO CLEAR
]. 
b.  To abort and return to the previous step press   or
 
 
6 
This menu is not displayed if Partition is enabled. 
7 
The display now prompts you to press [
<OK> TO RECALL
] i.e. to repeat the last used bypass scheme. To abort 
and return to the User Settings menu, press
 
. 
8 
You can now repeat steps 2 - 4 to bypass or clear another zone. To end this session and to select other menu 
options or to quit programming - follow the instructions in section A.2. 
9 
You can now select another option in the User Settings menu (see section A.1), or quit programming (see section 
A.2). 
B.4 Programming User Codes 
PowerMaster system allows you to authorize up to 8 (PowerMaster-10 G2) / 48 (PowerMaster-30 G2 / PowerMaster-33 
G2) people to arm and disarm the system by providing each with a unique 4 digit personal security code (code 0000 is 
not allowed), and assigning them with different security levels and functionalities. Moreover, you can obtain up to 8 
(PowerMaster-10 G2) / 32 (PowerMaster-30 G2 / PowerMaster-33 G2) multi-function portable keyfob transmitters that 
will allow you and the other users to easily arm, disarm and control the system without accessing the KP-250 PG2 or 
panel, including from outside the premises (see section B.7 Add / Delete Keyfob Transmitters). The Duress Code 
enables you to disarm the system using a special code that sends a silent alarm to the monitoring station. 
There are two types of users: Master User and User. The table below summarizes the different operations that can be 
performed by different users: 
User type  Function 
Master User 
 Arm/disarm 
 Zone bypass 
  Authorize other user codes 
 Set user codes 
  Report to private 
 Enroll/delete proximity tag 
 Enroll/delete keyfob 
 Automatic arming 
 Enable squawk 
  Set date and time format 
 Read event log 
  Programming the duress code 
  Programming the scheduler 
  Enabling/disabling voice option 
 Adjusting volume 
User 
 Arm/disarm 
 Zone bypass options 
The user codes are assigned as follows: 
User Code 1 is assigned to the Master User of the system (i.e. the owner). It is the only user code that allows access to 
the User Settings menu. The default setting of the Master User code is 1111. This code cannot be erased and must be 
replaced with a secret code as soon as possible. 
User Codes 2-4 (PowerMaster-10 G2) / User Codes 2-22 and 33-48 (PowerMaster-30 G2 / PowerMaster-33 G2) are 
assigned to family members, co-workers etc. They enable arming and disarming of the system or of selected partitions 
as defined by the Master User. They can access the "User Settings" menu only for "zone bypassing" provided this 
option is enabled in the Installer menu.