APPENDIX A: Specifications
D-304269 KP-250 PG2 User’s Guide 57
APPENDIX A: Specifications
Frequency Band (MHz)
Europe and rest of world: 433-434, 868-869 USA: 912-919
Communication Protocol
PowerG
Battery type
Four 1.5V AA Alkaline batteries
Battery Life Expectancy
3 years (for typical use).
Low Battery Threshold
3.8 V
Power source Battery: 4.8VDC – 6VDC
AC/DC (optional): 5VDC/2A - 12VDC/1A
Back light
Blue (keypad) / white (display)
Operating Temperature
0C to 55C (32F to 131F)
Humidity
verage relative humidity of approx. 75% non-condensing. For 30 days per year,
relative humidity may vary from 85% to 95% non-condensing.
Dimensions (WxLxD)
150x100x20mm (5-7/8 x 3-7/8 x 13/16 in)
Weight (including battery and bracket)
379 g (13 oz).
Mounting
Wall-mounted or desktop
Color
White
APPENDIX B: Partitioning
The KP-250 PG2 includes an optional partition feature. Partitioning is available only if your installer has enabled the
feature. Once partitioning is enabled Partitioning menus are added to the system which can be viewed on the LCD
display.
Each user code can be assigned to a combination of up to 3 partitions and each partition can be armed or disarmed
regardless of the status of the other partitions within the system. For example, you can define the garage as partition 1,
the basement as partition 2, and the house as partition 3. Since each partition is independent of other partitions, you can
arm or disarm each partition as desired without altering the states of the other partitions.
The system also supports a situation where an area is used by two or more partitions. For example, a reception area
which is common to two offices, each of which is assigned to a separate partition, will be armed only after both offices
(partitions) are armed. In the armed state the reception area will be disarmed after either office (partitions) has been
disarmed to allow the user of that office to use the reception area without generating an alarm. Such an area is termed a
"common area".
Note: Remote operation is performed per partition, or per user code defined for a particular partition, when partition is
enabled.
B1. Selecting a Partition
When operating in partition mode the first display will read:
P1: R P2: N P3: R
Press ; the display will read:
SELECT PARTITION
Press , , and to select the desired corresponding partition.
Note: After 5 seconds of no button press there will be a timeout and the display will revert to the All Partition display.
B2. Arming / Disarming the System
Before continuing, make sure that Partitioning has been enabled via the Installer Mode.
Arming/Disarming All Partitions
To arm/disarm all partitions in READY mode, press the / or button.