EasyManua.ls Logo

VOLTCRAFT LSG-10 - 11�3 Finding Cable Breaks with 2 Transmitters; Finding Errors in Electric Floor Heating

VOLTCRAFT LSG-10
100 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11.3 Finding cable breaks with 2 transmitters
Switch off the fuse and power down the electrical circuit�
This method makes it possible to locate the error from
two sides� A different signal code is set for each trans-
mitter� The receiver can be used to easily determine the
respective signal direction� The transmitter number is
indicated accordingly
Advantage: The two search signals will not interfere
with each other
When you have found the location of the fault, the re-
ceiver will no longer show any signal code, because
both signals have the same strength there�
The cable break must be high-impedance
(>100 kOhm)�
11.4 Finding errors in electric oor heating
Ensure that there is no insulating foil/mat with an earth
connection above the heating wires� If required, discon-
nect this earth connection before measuring, or the
error site will not be easy to locate� The signal should
be fed from both sides� It is more comfortable to use
a second transmitter unit with a different signal code�
40