Alarms that require special actions
Figure and text on information display Alarm level Action
Check
Regeneration cancelled Derate soon
- buzzer sounds
- amber central warning
1 Start regeneration at the
earliest opportunity.
Check
Parked regeneration required. Derate active
- buzzer sounds
- amber central warning
- engine performance is
reduced (restored after
regeneration)
1 Park the machine.
2 Start regeneration.
Check
Regeneration cancelled Derate active
- buzzer sounds
- amber central warning
- engine performance is
reduced (restored after
regeneration)
1 Start regeneration as soon as
possible.
Check
Apply parking brake Regeneration needed
- buzzer sounds
- amber central warning
1 Apply parking brake
2 Start regeneration.
Check
Service need. Regeneration not possible. System
failure
- buzzer sounds
- amber central warning
1 Service required. Contact an
authorized workshop.
Inform
Regeneration not needed
- green central warning 1 Continue normal use.
Regeneration does not have
to be started at this time.
196
Operating instructions
Exhaust aftertreatment system