www.vtiinstruments.com
EX1629 Command Set 95
Get Arm Count vtex1629_get_arm_count
Get Arm Delay vtex1629_get_arm_delay
Get Trigger Source vtex1629_get_trigger_source
Get Trigger Count vtex1629_get_trigger_count
Get Trigger Delay vtex1629_get_trigger_delay
Get Trigger Timer vtex1629_get_trigger_timer
Get Synchronization Source vtex1629_get_synch_source
Get Sample Clock Source vtex1629_get_sample_clock_source
Get Arm Pattern Configuration vtex1629_get_pattern_arm_configuration
Get Trig Pattern Configuration vtex1629_get_pattern_trig_configuration
Set Sample Count vtex1629_set_sample_count
Set Arm Source vtex1629_set_arm_source
Set Arm Count vtex1629_set_arm_count
Set Arm Delay vtex1629_set_arm_delay
Set Trigger Source vtex1629_set_trigger_source
Set Trigger Count vtex1629_set_trigger_count
Set Trigger Delay vtex1629_set_trigger_delay
Set Trigger Timer vtex1629_set_trigger_timer
Set Synchronization Source vtex1629_set_synch_source
Set Sample Clock Source vtex1629_set_sample_clock_source
Set Arm Pattern Configuration vtex1629_set_pattern_arm_configuration
Set Trig Pattern Configuration vtex1629_set_pattern_trig_configuration
Set Trigger Source Timer vtex1629_set_trigger_source_timer
Filter Configuration Calls
Get IIR Filter Configuration vtex1629_get_IIR_filter_configuration
Set IIR Filter Configuration vtex1629_set_IIR_filter_configuration
Get Settling Time vtex1629_get_settling_time
Excitation Voltage Calls
Get Programmed Excitation Voltage vtex1629_get_excitation
Get Excitation Voltage Enabled vtex1629_get_excitation_enabled
Set Programmed Excitation Voltage vtex1629_set_excitation
Set Excitation Voltage Enabled vtex1629_set_excitation_enabled
EU Conversion Calls
Get EU Conversion Type vtex1629_get_EU_conversion
Get EU Conversion Excitation Voltage vtex1629_get_euconv_excitation
Get Unstrained Voltage vtex1629_get_unstrained_voltage
Get Gage Factor vtex1629_get_gauge_factor
Get Poisson Ratio vtex1629_get_poisson_ratio
Get Strain Units vtex1629_get_strain_units
Get Tare Value vtex1629_get_tare
Set EU Conversion Type vtex1629_set_EU_conversion
Set EU Conversion Excitation Voltage vtex1629_set_euconv_excitation
Set Unstrained Voltage vtex1629_set_unstrained_voltage
Set Gage Factor vtex1629_get_gauge_factor
Set Poisson Ratio vtex1629_set_poisson_ratio
Set Strain Units vtex1629_set_strain_units
Set Tare Values vtex1629_set_tare
Get Linear Scaling Coefficients vtex1629_get_linearscaling_configuration
Set Linear Scaling Coefficients vtex1629_set_linearscaling_configuration
Measure Unstrained Voltage vtex1629_measure_unstrained_voltage
Measure Excitation Voltage vtex1629_measure_excitation_voltage
Measure Confidence vtex1629_measure_confidence
Reset Tare Values vtex1629_reset_tare
Set Dynamic Excitation EU Enabled vtex1629_set_euconv_dynamic_excitation_enabled
Get Dynamic Excitation EU Enabled vtex1629_set_euconv_dynamic_excitation_enabled