6 Use and operation DPU 100-70Les
28 Operator's manual
6.2 Starting up
Starting the engine
1. Set the throttle lever to the full throttle position.
2. To turn the vibration off, press the vibration on/off switch.
Note: The engine starts only if the vibration is turned off.
3. Insert the key into the ignition lock and turn to the right.
4. Press the start button and do not let go until the engine is running.
5. Shift the throttle lever to the idle position.
6. Let the engine warm up for a few minutes
Item Designation Item Designation
1 Start button 6 Stand vibration/normal operation
switch
2 Vibration control lamp 7 Charging control lamp
3 Slow/fast operation button 8 Oil pressure control lamp
4 Vibration on/off switch 9 Ignition lock
5 Throttle lever