7 Maintenance DPU 100-70Les
32 Operator's manual
7 Maintenance
7.1 Maintenance schedule
WARNING
Improper handling can result in injury or serious material damage.
f Read and follow all safety information of this operator's manual, see chapter
Safety.
Maintenance work Daily Weekly Monthly Every
250 hours
Every
500 hours
Visual inspection of all parts for
damage.
Check fuel level.
Check engine oil level.
Check/clean oil bath air
cleaner.
Top up or change the oil if nec-
essary.
Check whether the fins of the
oil cooler are dirty. If necessary,
clean the oil cooler with water
jets (minimum distance 20 cm).
Do not use a high pressure
washer.
Grease the thread of the center
pole height adjustment.
Change drive motor engine oil
and oil filter.
After the first 25 hours.
Check hydraulic oil level.
Check exciter oil level.
Check battery acid level.
Have exciter oil changed. *
Change drive motor engine oil
and oil filter.
Clean the cooling fins of the
drive motor using a brush.