40
PXM
OPERATING AND ASSEMBLY MANUAL
VERSION 08/2015 ORDER NUMBER DOC2350372
Interface
Communication with the application controller: No
Injectors
Preliminary cleaning Block 1
Number of pulses: 2
Pulse time: 0.2 secs
Break time: 1 secs
Preliminary cleaning Block 2
Number of pulses: 2
Pulse time: 0.2 secs
Break time: 1 secs
Cleaning Block 1
Number of pulses: 8
Pulse time: 0.5 secs
Break time: 2 secs
Cleaning Block 2
Number of pulses: 8
Pulse time: 0.5 secs
Break time: 2 secs
Dynamics: O
FP supply
Pre-cleaning
Number of pulses: 2
Pulse time: 0.5 secs
Break time: 2.0 secs
Cleaning
Pulse time: 1.0 secs
Break time: 2.0 secs
RP supply
Cleaning
Number of pulses: 10
Pulse time: 1.0 secs
Break time: 2.0 secs
US sieve
Pre-cleaning
Number of pulses: 5
Pulse time: 0.2 secs
Break time: 2.0 secs
Cleaning
Number of pulses: 5
Pulse time: 0.5 secs
Break time: 2.0 secs