11
VERSION 01/2018
ORDER NUMBER DOC 2316596
Cleaning
If there are deposits on the surfaces, the device may form electrostatic charges. Flames
or sparks can form during discharge.
Remove deposits from the surfaces to maintain conductivity.
Use only a damp cloth to clean the device.
Air in the pump uid
Ignitable gas mixtures can form if air enters the pump uid.
Prevent the pump from taking in air and running dry.
If air has been taken in, x the leak. Then, ll slowly and in a controlled manner until
the air has escaped.
Air in the pumped uid can be caused by damaged packings.
Avoid operating the pump with damaged packing.
Ensure that the separating agent tank is lled with sucient separating agent.
Periodically check that the pump is working smoothly, paying special attention to
the presence of air in the pumped uid.
Filling and emptying
Ignitable gas mixtures can form in the uid section or product hoses if the pump must
be emptied for maintenance and/or repair purposes.
Empty and ll the device slowly and in a controlled manner.
Avoid potentially explosive atmosphere in the surroundings.
3.3 TYPE PLATES
Designation
1 Manufacturer and CE Identication
2 Pump type
3 Maximum product pressure
4 Pump ratio
5 Flow rate per double stroke
6 Maximum air inlet pressure
7 Maximum product temperature
8 Model year - serial number
9 Read operating manual before use!
1
2
4
5
6
7
8
9
3
Pumpentyp / Pump type
Max. Materialdruck / Fluid pressure
Übersetzungsverhältnis / Ratio
Fördermenge DH / Delivery DS
Max. Luftdruck / Air pressure
Max. Temp. Material / Fluid
Baujahr - Serie Nr. / Year of manufacture - Serial No.
Vor Gebrauch Betriebsanleitung beachten / Check manual before use!
Wagner International AG
MADE IN SWITZERLAND
CH-9450 ALTSTÄTTEN
II 2 G Ex h IIB T3/T4 Gb X