EasyManua.ls Logo

WAGNER EvoMotion 5-125 - Technical Data

WAGNER EvoMotion 5-125
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
VERSION 01/2018
ORDER NUMBER DOC 2316596
5.5.3 TECHNICAL DATA
Description Unit
Pump ratio 5:1
Volume ow per double stroke (DH) 125
Maximum operating overpressure
4.0
40
581
Maximum possible strokes in operation 60
Minimum/maximum air inlet pressure
0.2–0.8
2–8
28–116
Compressed air quality: free from oil and water
Quality standard 7.5.4 according to ISO 8573.1,
2010
7: Particle concentration 5–10mg/m³
5: Humidity: pressure dew point ≤ 7 °C
4: Oil content ≤ 5mg/m3
Air inlet (inside thread) 8.0; 0.31
Minimum Ø of the compressed air supply line 9.0; 0.35
Air consumption at 0.6 MPa; 6 bar; 87 psi per double
stroke
4.0; 0.14
Sound pressure level at maximum permissible air
pressure*
72
Sound pressure level at 0.6 MPa; 6bar; 87psi air
pressure*
69
Sound pressure level at 0.4 MPa; 4bar; 58psi air
pressure*
62
Air motor piston diameter 80; 3.15
Product inlet (inside thread) --
Product outlet (inside thread) G 1/2“
Weight 25; 55
Maximum product pressure at pump inlet
--
--
--
Product temperature
5–80
41–176
Ambient temperature
5–60
41–140
Allowable inclination for operation 10
* Measured A-rated emission sound pressure level at distance of 1m, LpA1m in accordance with DINEN14462:
2015. Reference measurements have been made by Suva (Swiss National Accident Insurance Fund).
WARNING
Exhaust air containing oil!
Risk of poisoning if inhaled.
Provide compressed air free from oil and water.