8.2.3.2 PRODUCT HOSES, PIPES AND COUPLINGS
The service life of the complete hoses between product pressure generator and application
device is reduced due to environmental inuences even when handled correctly.
Check hoses, pipes, and couplings every day and replace if necessary.
Before every commissioning, check all connections for leaks.
Additionally, the operator must regularly check the complete hoses for wear and
tear as well as for damage at intervals that he/she has set. Records of these checks
must be kept.
Undamaged complete hoses are to be replaced when one of the two following
intervals has been exceeded:
−6 years from the date of the hose crimping (see tting embossing).
−10 years from the date of the hose imprinting.
Fitting embossing Meaning
xxx bar Pressure
yymm Crimping date (year/month)
XX Internal code
Hose imprinting Meaning
Wagner Name / Manufacturer
yymm Date of manufacture (year/month)
xxx bar (xx MPa)
e.g., 270 bar (27 MPa)
Pressure
XX Internal code
DNxx (e.g., DN10) Nominal diameter

Table of Contents

Other manuals for WAGNER EvoMotion 5-125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER EvoMotion 5-125 and is the answer not in the manual?

WAGNER EvoMotion 5-125 Specifications

General IconGeneral
BrandWAGNER
ModelEvoMotion 5-125
CategoryWater Pump
LanguageEnglish

Related product manuals