6.4.5 GROUNDING
Perfect grounding of all conductive parts such as oors, walls, roofs is important for
optimum coating and safety. Barriers, work pieces, transport devices, coating product
tank, coating product supply or construction parts in the spray area with exception of the
high-voltage parts during normal operation.
Parts of the booth must be grounded in accordance with EN 12215.
Discharge of electrostatically charged components in
atmospheres containing solvents!
Explosion hazard from electrostatic sparks or ames.
Ground all device components.
Ground the work pieces to be coated.
WARNING
Heavy paint mist if grounding is insu cient!
Danger of poisoning.
Insu cient paint application quality.
Ground all device components.
Ground the work pieces to be coated.
WARNING
A poorly grounded work piece causes:
very bad wrap around.
uneven coating.
Back spraying to the spray gun, i.e. contamination.
Prerequisites for perfect grounding and coating are:
Clean work piece suspension.
Grounding of spray booth, conveyor system and suspension on the building side in
accordance with the operating instruction or the manufacturer's information.
Grounding of all conductive parts within the working area.
The grounding resistance of the work piece may not exceed 1 MΩ (Mega Ohm).
Note:
Resistance to ground measured at 500 V or 1000 V.
Connect the control unit to the system ground.