WL2FLT Manual Page 51 Revision 10-26-2021
10. Dispenses Hot and Cold Water at the same time
Possible Reason
Solution
Too much water pressure.
Recommend 40 to 60 psi for
the WL2FLT Water Treatment
System to operate properly.
The correct input water pressure is critical to the performance of the
unit to allow solenoids to open.
Check water pressure at the inlet bulkhead with a water pressure
gauge.
Additional method of verification is to turn off water to unit and
press the dispense button. Does the solenoid open without water
pressure to the unit? Listen for solenoid to activate, not button
“click”.
Adjust water pressure to 40-60 psi.
Hot or Cold solenoid is stuck
open.
Remove Top Cover.
Check Hot Solenoid: Dispense cold water and visually inspect tubing
for water flow from both tanks.
Check Cold Solenoid: Disconnect Elbow from outlet of Cold
Solenoid. Select hot water and dispense (quickly releasing
Dispensing Button to avoid much water coming out of Cold Solenoid.
Replace Solenoid as necessary.