Model
2001
OPERATING INSTRUCTIONS
@
MARKERS
0
WIDTH SlZE
-
Dual concentric control; outer knob adjusts marker width from 15 to 400 kHz in
four steps; inner knob controls marker size.
@
MARKERS
-
Six push button switches control A1 and A2 Marker Options (Marker frequency
is engraved on push button).
0
TI LTINORM Switch
-
Provides vertical markers in the NORM (down) position. In the TILT (up) posi-
tion provides horizontal markers having a fixed amplitude of approximately 10%
of the horizontal display, when MARKER
SlZE
is
set to minimum.
NOTE: Increasing the marker size will cause the horizontal marker to tilt toward
a
vertical position. This feature is used to identify frequencies on Steep response
skirts.
@
MARKER SlZE Switch
-
@
SCOPE HORIZ. Out
-
@
SCOPE VERT. Out
-
@
OUTPUT-dBm-50 ohm
-
0
RF out
-
@
MARKER
in
-
@
MOD
-
@
ALC
in
-
EXTANT Switch
-
@
POWER
-
This three position switch provides; large markers in its Lower position
(12
V to
50mV peak-to-peak), small markers in its Center position
(50mV to 100uV volts
peak-to-peak) and rectified positive markers in its Up position. These rectified
markers are for use with
X-Y recorders.
BNC connector provides a 16 volt peak-to-peak triangle wave, symmetrical about
ground, to drive the Horizontal
(x) axis of the oscilloscope or other indicating
device. (An alternate connection is available at the Rear Panel).
BNC connector provides the combined markers and demodulated RF
(when
DEMOD in is connected) for connection to the oscilloscope Vertical
(y) axis
input.
BNC connector accepts the demodulated, swept, signal from the device under test
so RF markers may be added. (The combined signal is available at the SCOPE
VERT. OUTPUT connector).
Attenuator; Outer knob providescalibrated adjustment of the RF output in 10 dB
increments from
0 dBm to -70 dBm; inner knob provides calibrated vernier ad-
justment of the RF output from +10
dBm to -10 dBm.
BNC connector provides a connection for RF output signal.
BNC connector accepts an externally generated continuous wave signal to produce
a frequency marker on the display.
Push button switch for A4 option (1 kHz square wave amplitude modulation).
BNC connector accepts an automatic leveling control signal from a remote moni-
tor when
EXTIINT switch is in the EXT (up) position.
Closes the internal automatic leveling loop when in INT (down) position.
NOTE: When this switch is in the EXT position, and no external monitor is in
use, the RF output is unleveled and not controlled by the 20dB vernier
attenua-
tor.
Push button applies A.C. power to the power supply. The light indicates that the
instrument is operating.
Model
2001
(§)
MARKERS
0
WIDTH.
SIZE
-
(§)
MARKERS
-
(j)
TILT/NORM
Switch-
(])
MARKER
SIZE
Switch
-
@ SCOPE
HORIZ.
Out
-
@ SCOPE
VERT.
Out-
@
DEMOD
in-
@
OUTPUT·dBm-50
ohm
-
@ RF
out-
@
MARKER
in-
@MOD-
@
ALC
in-
@
EXT/INT
Switch
-
@
POWER-
OPERATING INSTRUCTIONS
Dual concentric
control;
outer
knob
adjusts marker
width
from
15
to
400
kHz
in
four
steps; inner
knob
controls
marker size.
Six push
button
switches
control
A 1 and
A2
Marker
Options
(Marker frequency
is
engraved on push
button).
Provides vertical markers in the
NORM
(down)
position.
I n the
TI
L T (up) posi-
tion
provides
horizontal
markers having a
fixed
amplitude
of
approximately
10%
of
the horizontal display, when
MARKER
SIZE
is
set
to
minimum.
NOTE:
I ncreasing the
marker
size
will
cause the
horizontal
marker
to
tilt
toward
a vertical
position.
This feature is
used
to
identify
frequencies on Steep response
skirts.
This three position
switch
provides; large markers in its
Lower
position
(12
V
to
50mV
peak-to-peak), small markers in its Center
position
(50mV
to
100uV
volts
peak-to-peak) and rectified positive markers in its
Up
position. These rectified
markers
are
for
use
with
X-V
recorders.
BNC connector provides a 16
volt
peak-to-peak triangle wave, symmetrical
about
ground,
to
drive the
Horizontal
(x) axis
of
the oscilloscope
or
other
indicating
device.
(An
alternate connection
is
available
at
the Rear Panel).
BNC connector provides the combined markers and demodulated RF (when
DEMOD in
is
connected)
for
connection
to
the oscilloscope Vertical (y) axis
input.
BNC connector accepts the demodulated, swept, signal
from
the device under test
so
RF markers may
be
added. (The combined signal
is
available
at
the SCOPE
VERT.
OUTPUT
connector).
Attenuator;
Outer
knob
provides calibrated adjustment
of
the R F
output
in 10
dB
increments
from
0
dBm
to
-70
dBm;
inner
knob
provides calibrated vernier
ad-
justment
of
the
RF
output
from
+10
dBm
to
-10
dBm.
BNC connector provides a connection
for
R F
output
signal.
BNC connector accepts
an
externally
generated
continuous
wave signal
to
produce
a frequency
marker
on
the display.
Push
button
switch
for
A4
option
(1
kHz
square wave
amplitude
modulation).
BNC connector accepts
an
automatic
leveling
control
signal
from
a
remote
moni-
tor
when
EXT/INT
switch
is
in the
EXT
(up) position.
Closes the internal
automatic
leveling loop when in I
NT
(down)
position.
NOTE:
When
this
switch
is
in the
EXT
position,
and
no
external
monitor
is
in
use,
the
RF
output
is
unleveled and
not
controlled
by
the
20
dB
vernier attenua-
tor.
Push
button
applies A.C.
power
to
the
power
supply.
The
light
indicates
that
the
instrument
is operating.
3-3