Model
2001
GENERAL INFORMATION
TABLE
1-1.
Specifications (Con't.)
band end and +16 volts to HIGH frequency band end)
Tuning sensitivity: 16
MHzIvolt (approx.)
Sweep Width
-
Vernier 0-20 dB
OU~DU~
-
External FM
-
External AM
-
SWEEP SPECIFICATIONS
Sweep Modes
-
Sweep time
-
Horizontal Output
-
EXTERNAL LEVELING
External Monitor
(ALC)
-
MARKER SPECIFICATIONS
Accuracy
-
May be controlled by a remote potentiometer. (Input and
output connections provided in Rear Panel REMOTE jack)
May be remotely programmed over a 20 dB range with a
0 to -18 volt signal. (-18 volts corresponds to a maximum
output)
Full deviation of
5250 MHz possible at rates up to 4kHz.
With reduced deviation and linearity, modulation rates to
100kHz are possible. Sensitivity: 16 MHz/volt (approx.)
External AM signals are applied to same connections as
for vernier
0-20 dB control. Therefore, vernier range must
be restricted so the
0 to -18 volt range is not exceeded or
distortion will occur. With average voltage set to mid-range,
100% modulation is possible to
IkHz, 40% modulation
possible to a
40kHz rate.
Repetative sweep
Single sweep
Externally triggered sweep
Manual sweep
Line lock sweep
Continuously variable from less than 10 ms to over 100
seconds, in 4-decade steps, plus vernier
16 volts peak-to-peak (symmetrical about ground)
An external negative signal, between 0.2 and 2 volts,
may be used to level the RF output
Birdy by-pass markers with provisions for six plug-in
marker modules, plus Front Panel external marker input.
Markers may be either single frequency or harmonic
(comb.) type. (See Options
A1 and A2)
Model
2001
Sweep
Width
-
Vernier
0-20
dB
Output
-
External
FM -
External
AM
-
SWEEP
SPECIFICATIONS
Sweep Modes -
Sweep
time
-
Horizontal
Output
-
EXTERNAL
LEVELING
External
Monitor
(ALC)
-
MARKER
SPECIFICATIONS
Type
-
Accuracy
-
GENERAL
INFORMATION
TABLE 1-1. Specifications (Con't.)
band end and
+16
volts
to
HIGH
frequency
band end)
Tuning
sensitivity:
16
MHz/volt
(approx_)
May
be
controlled
by
a
remote
potentiometer.
(Input
and
output
connections
provided
in Rear Panel
REMOTE
jack)
May
be
remotely
programmed
over a
20
dB
range
with
a
o
to
-18
volt
signal. (-18
volts
corresponds
to
a
maximum
output)
Full
deviation
of
±250
MHz
possible
at
rates
up
to
4kHz_
With
reduced
deviation
and
linearity,
modulation
rates
to
100kHz
are possible.
Sensitivity:
16
MHz/volt
(approx.)
External
AM
signals are applied
to
same
connections
as
for
vernier
0-20
dB
control.
Therefore,
vernier
range
must
be restricted
so
the 0
to
-18
volt
range
is
not
exceeded
or
distortion
will
occur.
With
average voltage set
to
mid-range,
100%
modulation
is
possible
to
1kHz,
40%
modulation
possible
to
a
40kHz
rate.
Repetative sweep
Single sweep
Externally
triggered sweep
Manual sweep
Line
lock
sweep
Continuously
variable
from
less
than
10
ms
to
over
100
seconds, in 4-decade steps, plus vernier
16
volts
peak-to-peak
(symmetrical
about
ground)
An
external
negative signal, between
0.2
and 2
volts,
may
be used
to
level
the
R F
output
Birdy
by-pass markers
with
provIsions
for
six
plug-in
marker
modules, plus
Front
Panel
external
marker
input.
Markers
may
be
either
single
frequency
or
harmonic
(comb.)
type.
(See
Options
A 1 and
A2)
0.005%
1-3