10
Part No. 920559 Rev H November 2008
2.6 Electrical Wiring, continued
7. Trim wires to appropriate length, terminate ends and connect to the terminal block as per Wiring Diagram
drawing 888445-001 located in the Appendix B of this manual. Note: Field wires are to be connected to
the lower terminals on the block.
8. Prepare the potting compound by pouring 4 oz. Rockite into an eight oz. paper cup.
9. Add 1-1/2 oz. of water.
10. Stir one to two minutes until reaching a consistency similar to pancake batter.
11. Pour mix into fitting and fill to within 1/8” of top of fitting (or top of conduit if the Ethernet conduit).
12. Close the service door.
13. Let fitting set for 12 hours. The wires must not be moved during this time.
Photo 1. Photo 2.
Photo 3. Photo 4.