23
November 2008 Part No. 920559 Rev H
3.4 Setting the Clock
The time and date is set in function F02 Clock Configuration. The sub-functions F02.00 is the time
HH.MM, F02.01 is the date MM.DD and F02.02 is the year YY.YY.
1. Press ENTER
PA S S 1 (enter password)
2. Press ENTER
PA S S 2 (enter password)
3. Press ENTER. The unit price display will show F— (indicating it needs a function number to proceed)
4. Press 02 to access F02
5. Press ENTER. The unit price display will show F02 (indicating the function has been accessed)
6. Press ENTER to access the sub-functions of F02. The unit price display will show 2.00
3.5 Setting Unit Prices
The procedure below is used to set the dispenser unit prices when operating in stand alone mode or when
communication with the POS system is disabled. When communication with the POS system is enabled,
the system will not allow unit price setting at the dispenser.
The pump computer recognizes code stored in memory that defines a dispenser model and assigns logical
nozzle numbers to the hose positions as discussed in the previous sections. To set unit prices on side 1 and
side 2, functions F03 and F04 are accessed using the remote control interface. Credit prices on side 1 are
set using sub-functions F03.0N while cash prices are set using sub-functions F03.1N, where N is the logi-
cal nozzle number. Active values of N are given in Table 3-1. For side 2, the corresponding sub-functions
are F04.0N and F04.1N, respectively.
To set the unit price, the correct sub-function is accessed, the unit price is changed to its new value and the
data is saved. To access the desired sub-function, perform the following steps using the remote control.
Bold type denotes remote control function; italicized type denotes dispenser response.
Accessing the Unit Price Sub-function for Side 1.
1. Press ENTER
PA S S 1 (enter password)
2. Press ENTER
PA S S 2 (enter password)
3. Press ENTER. The unit price display will show F— (indicating it needs a function number to proceed)
4. Press 03 to access F03
5. Press ENTER. The unit price display will show F03 (indicating the function has been accessed)
6. Press ENTER to access the sub-functions of F03. The unit price display will show 3.01
At this point, pressing of NEXT will advance the sub-function to the next sub-function, incrementing the
value of N by (.01). For example, to access F3.02, press NEXT. The unit price display will show 3.02,
press NEXT. The desired sub-function depends on the dispenser type. Table 3-1 shows the values of N
that define the desired sub-functions for the dispenser models shown. Once the desired sub-function is
accessed, the price display will
show “– – – – – –“ and the volume display will show the current value of the unit price. The following pro-
cedure must then be followed to set the unit price.