32
Part No. 920559 Rev H November 2008
3.12 Nozzle Boot Switch Check
In the Ovation style nozzle boot, a proximity switch and a magnetic actuator are used for nozzle on/off
operation. The proximity switch is attached to the back of the nozzle boot casting. The magnetic actua-
tor is located inside the spring-loaded flipper, which is installed from the top front of the boot casting.
When the nozzle is removed, the flipper rotates the magnetic actuator and aligns the actuator with the
proximity switch, turning the switch on. There is no adjustment for the switch.
Check the operation of the nozzle switch as follows:
Step 1 Authorize the dispenser and remove the nozzle from the nozzle boot to make sure the switch
turns on. An on switch will be indicated by the lighted Push-to-Start buttons and the unit price
displays blinking.
Step 2 Insert nozzle slowly into the nozzle boot and check that the switch turns off. An off switch is
indicated by the lighted Push-to-Start buttons turning off and the unit price displays stop
blinking.
3.13 Annunciator Operation Check
Check that the annunciator is operating properly on each side of the dispenser. When pressing the keys
on the CAT keypad or the Push-to-Start/Grade Select buttons on the bezel, you should hear the annunci-
ator beep.
3.14 QCAT Dispensers and CAT Address
Check the operation of the Customer Activated Terminal (CAT) by performing the QCAT self-test pro-
cedure in Appendix A1 of this manual. The procedure includes setting the CAT ID address. The CAT
address is normally set to the same address as the pump fueling point address for that side of the dis-
penser.
For dispensers equipped with the iX option, refer to Section 3.19.
3.15 IX
PAY Secure Payment
Follow the procedures in the Secure Payment Module (SPM) Startup and Service manual, part number
000-940014-, for diagnostic test, configuration, and putting the SPM into operation.
3.16 Wayne Vac Motor Operation
For dispensers equipped with Wayne Vac, verify that the correct vacuum pump motor is running when
dispensing product. Verify by checking that air is being drawn through the vapor return hole(s) in each
nozzle spout.
Also see the Wayne Vac Compliance Testing and Preventative Maintenance manual, part number
917947.