27
November 2008 Part No. 920559 Rev H
3.7 Setting the Fueling Point ID
The procedure below is used to set the pump fueling point address. The pump FPID should be input and
saved before control is transferred to the POS system.
Functions F05 and F06 are accessed to set the FPID on Side 1 and Side 2, respectively. To set the FPID, the
desired FPID must be input and saved.
Accessing the FPID Function.
1. Press ENTER
PASS 1 (enter password)
2. Press ENTER
PASS 2 (enter password)
3. Press ENTER. The unit price display will show F— (indicating that it needs a function number to pro-
ceed)
4. Press 05 to access F05
5. Press ENTER. The unit price display will show F05 indicating the function has been accessed and the
volume display will show the current FPID or a 0” when no FPID has been assigned to that dispenser
side.
6. Input the desired FPID by using the UP and DOWN keys on the remote control interface followed by
ENTER, or by typing the # sign followed by the valve of the FPID followed by ENTER.
7. Repeat the procedure for Side 2.
Saving the New FPID
1. Press ENTER. The price display will show “– – – – – –“, the volume display will be blank and the unit
price display will show the last sub-function accessed.
2. Press 00 (to access F00)
3. Press ENTER. The unit price should now display F00, the price display will show “– – – – – –“and the
volume display will be blank.
4. Press ENTER and the volume display will show a 1.
5. Press UP twice to change the value in the volume display from 1 to 3.
6. Press ENTER
7. The volume display should show a 3.
8. Press ENTER. CHANGE STORED should appear on the display momentarily. The display should return
to normal in a few seconds. When it does, the unit price displays should show the new prices. If they do
not show the desired unit prices, access the appropriate sub-function to make sure that the unit price data
is correct.
8. Repeat the procedure for Side 2.
Note: For models equipped with IDPOS, see configration in Section 4.