57
November 2008 Part No. 920559 Rev H
APPENDIX A2
OVATION iX CAT SELF-TEST PROCEDURE
1. Press reset button on the iX board.
Note: A screen will be displayed showing “iX Ovation” with an activity bar moving across the bot-
tom of the screen. When the activity bar has completed, the screen becomes dark briefly and
then the screen prompts System Initializing is displayed for a several few seconds, Dispenser
Manager Initializing is displayed briefly and then the VGA Screen Orientation prompt is dis-
played (Screen Contrast on QVGA). If there are no softkeys, press Yes, No or Cancel on the
keypad as appropriate during this procedure.
Refer to the iX CAT Software Installation manual, part number 920880, if more details are
needed on the above screen sequence or if iX CAT software installation is required.
2. At the “One Moment Please” prompt, immediately press and release softkey 2 (left side 2
nd
down) or press 1 on the keypad for QVGA without softkeys.
Note: If you miss the prompt, the screen will stay on the “Dispenser Manager Starts” message
for several seconds and then go back to the online prompt screen, or to the offline
prompt if the POS is offline.
Note: Softkey 1 is upper left softkey, softkey 5 is upper right softkey.
3. Press Yes softkey at the prompt “Want to Test Bezel Devices”. This will begin the diagnostic test.
Note: At startups, always select YES to this prompt and test the peripheral devices.
4. At the Softkey Test screen, verify each softkey is working properly by pressing each softkey and
then press the Cancel softkey after the test.
5. At the Keypad Test screen, press each key and verify each digit shows on the display. Press
Cancel softkey when finished and the Card Reader test will begin.
6. At the “Please Insert Card or Press Cancel” prompt, insert a card or scan a bar code and the
screen will display: “Track #1 Data: %# # # # # #..................#
“Track #2 Data: %# # # # # #..................#
At this point, pressing the Help softkey will allow you to insert another card or scan a bar code and/
or press Cancel and the Printer test will automatically print a receipt, and the Printer Status win-
dow will display “Printer online” or “Printer offline”.
7. The Pump Test CAN Bus Test screen will be displayed. This screen will verify that the CAN bus is
working properly by displaying the following information:
“Pump Rev __
Nozzle Status __
Grade Selected __
Note: If the pump iGEM software revision number, for example 43.00, is not displayed after the
“Pump Rev”, the CAN bus connections may be faulty, disconnected, or side A and B
may be set backwards.