40 | Flameproof motors
www.weg.net
Lubrication intervals for horizontal mounted ribbed
cooled and tube cooled motors (50Hz and 60Hz)
operating at an ambient temperature range -20ºC
up to +40ºC or -55ºC up to +40ºC are present in the
Table 8-2.
Table 8-2 Ball bearings lubrication intervals for
horizontal mounting
BALL BEARING
Bearing
Poles
Operating Hours (h)
Grease
Quantity (g)
50Hz
60Hz
6314
2
4500
3200
26
6316
2
3600
2300
33
4
4500
4500
6
8
6318
2
2800
1700
41
6319
4
4500
4500
45
6
8
6322
4
4500
4500
60
6
8
6324
4
4500
4300
72
6
4500
8
6326
4
4500
3700
81
6
4500
8
6328
4
4500
3200
93
6
4500
8
6330
4
4100
2700
104
6
4500
4500
8
6332
4
3600
2300
116
6
4500
4500
8
As an option, horizontal motors can be equipped
with roller bearings. Lubrication intervals for
horizontal mounted ribbed cooled and tube cooled
motors (50Hz and 60Hz) operating at an ambient
temperature range -20ºC up to +40ºC or -55ºC up
to +40ºC are present in the Table 8-3:
Table 8-3 Roller bearings lubrication intervals for
horizontal mounting
ROLLER BEARING
Bearing
Poles
Operating Hours (h)
Grease
Quantity (g)
50Hz
60Hz
NU218
2
1200
1000
24
NU220
2
1000
-
31
NU319
4
3500
2500
45
6
4500
4500
8
NU322
4
2400
1600
60
6
4500
3500
8
4500
NU324
4
2000
1300
72
6
3900
3000
8
4500
4500
NU326
4
1700
1000
81
6
3500
2600
8
4500
4000
NU328
4
1400
1000
93
6
3000
2200
8
4400
3500
Lubrication intervals for horizontal mounted ribbed
cooled and tube cooled motors (50Hz and 60Hz)
with special mounting of two (2) bearings (one (1)
roller bearing and one (1) ball bearing) operating at
an ambient temperature range -20ºC up to +40ºC
or -55ºC up to +40ºC are present in the Table 8-4:
Table 8-4 Roller and Ball bearings lubrication intervals
for horizontal mounting
ROLLER BEARING + BALL BEARING
Bearing
Poles
Operating Hours (h)
Grease
Quantity (g)
50Hz
60Hz
NU220+
6020
2
1000
-
31+18
NU234+
6034
4
1000
1000
81+55
6
2600
1800
8
3900
3000
NU238+
6038
4
1000
1000
94+68
6
2100
1400
8
3300
2500
NU328+
6328
4
1400
1000
93+93
6
3000
2200
8
4400
3500
Lubrication intervals for vertical mounted ribbed
cooled motors (50Hz and 60Hz) operating at an
ambient temperature range -20ºC up to +40ºC or -
55ºC up to +40ºC are present in the Table 8-5 and
Table 8-6:

Table of Contents