ATA Web user guide
106 / 114 2015/1/8
Item Decription
length is 5 bytes with a range of 0~65535.。
On Time 1 Default: 50; Set up the first category of ON time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
Off Time 1 Default: 50; Set up the first category of OFF time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
On Time 2 Default: 0; Set up the second category of ON time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
Off Time 2 Default: 0; Set up the second category of OFF time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
On Time 3 Default: 0; Set up the third category of ON time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).。
Off Time 3 Default: 0; Set up the third category of OFF time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
Congestion Set up the Congestion Tone Settings.
Cadence On Default: Enable; When check the box, Cadence On will Enable.
Hi-Tone Freq Default: 620; This column can only enter numbers; maximum
length is 4 bytes with a range of 0~4096.
Lo-Tone Freq Default: 480; This column can only enter numbers; maximum
length is 4 bytes with a range of 0~4096.
Hi-Tone Gain Default: 2261; This column can only enter numbers; maximum
length is 5 bytes with a range of 0~65535.
Lo-Tone Gain Default: 2261; This column can only enter numbers; maximum
length is 5 bytes with a range of 0~65535.
On Time 1 Default: 30; Set up the first category of ON time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
Off Time 1 Default: 20; Set up the first category of OFF time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
On Time 2 Default: 0; Set up the secondsond category of time start.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
Off Time 2 Default: 0; Set up the second category of OFF time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
On Time 3 Default: 0; Set up the third category of ON time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
Off Time 3 Default: 0; Set up the third category of OFF time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
Ring Set up the Ring Tone Settings.
Cadence On Default: Enable; When check the box, Cadence On will Enable.