6-6
CONTROL PANEL TEST LOCATIONS
TECH SHEET 4452022A
COMPONENTS
FRONT/REAR
SERVICEABLE
CHECK POINTS RESULTS
Door Switch Front
Door Open =
Closed Circuit
Door Closed =
Open Circuit
Door Lock
Solenoid
Front
Oven
Temperature
Sensor
Front 1080
Blower Rear 10
to 15
Oven Shutdown
Thermal Fuse
Rear Closed Circuit
Bake Element Front 25
to 30
Broil Element Front 45
to 55
Convection Fan
Motor
Rear 8
to 12
Control Panel
Thermal Fuse
Front Closed Circuit
Latch Switch Front
Door Unlocked =
Open Circuit
Door Locked =
Closed Circuit
LOWER OVEN UPPER OVEN
COMPONENTS
FRONT/REAR
SERVICEABLE
CHECK POINTS RESULTS
Door Switch Front
P3-5 (BR/W) to
P3-1 (TAN)
P3-3 (BR) to
P3-1 (TAN)
Door Open =
Closed Circuit
Door Closed =
Open Circuit
Front
50
50
Oven
Temperature
Sensor
Front 1080
@ 70
°
F @ 70
°
F
Blower (Low) Rear 10
to 15
Oven Shutdown
Thermal Fuse
Rear Closed Circuit
Bake Element Front 25
to 30
Broil Element Front 45
to 55
Door Lock
Solenoid
P4-4 (Y) to
Neutral (W)
P4-7 (Y) to
Neutral (W)
P4-8 (OR) to
Neutral (W)
P3-2 (BU) to
P3-1 (TAN)
L1 (BK) to
P7-1 (BK)
Sensor
P2-2 (V/W) to
P2-1 (V/W)
Sensor
P2-3 (V) to
P2-4 (V)
P4-3 (GY) to
Neutral (W)
P4-6 (GY) to
Neutral (W)
P6-1 (OR) or
P6-2 (R) to
Red Wire At
Terminal Block
P6-3 (R) or
P6-4 (OR) to
Red Wire At
Terminal Block
P6-2 (R) to
Red Wire At
Terminal Block
P6-1 (OR) to
Red Wire At
Terminal Block
P6-3 (R) to
Red Wire At
Terminal Block
P6-4 (OR) to
Red Wire At
Terminal Block

Table of Contents