Page 2 | 1-800-343-9463
PS 020713
WALL MOUNTED PLATINUM SPLIT UNIT SPECIFICATIONS
Model
4000 Evaporator
(Fan Coil Unit)
4000 Condenser
(Air Cooled
Condensing Unit)
8000 Evaporator
(Fan Coil Unit)
8000 Condenser
(Air Cooled
Condensing Unit)
Cellar Size (cu. ft.) 1000 2000
Dimensions 20.5”w x 15.5”h x 14.5”d 12”w x 13.5”h x 18”d 20.5”w x 15.5”h x 14.5”d 12”w x 13.5”h x 18”d
BTUh with 90° air entering
the Condenser Coil
3650 4450
CFM
270 190 278 350
Refrigerant R-134a
Condensing Unit HP 1/3++ 1/2
Voltage Rating
(20 amp
dedicated circuit required)
115V or 230V
Weight (lbs) 56 56 56 66
AMPS
(Starting/Running) 2/1 13/8.6 2/1 18/9.5
dBA 54 65 54 65
Drainline 1/2” Condensate
Installation
Evaporator Unit (Fan Coil Unit) is installed in the cellar or up to 25 ducted ft. away, condenser is
installed up to 100 ft
Thermostat Digital Control Display
Temp. Delta 55°F
Temperature dierential between the cellar temperature and condenser air intake temperature.
Warranty 2 year parts and labor
QUICK REFERENCE GUIDE
Controller Layout
Refer to page 33 for complete listing of buttons and symbols.
°
F
Compressor On
Fans are On
Unit is in Anti-Frost Mode
Unit is in Pre-Chill Mode
Alarm is Present
View Set Point
Change Set Point
(Press and hold 3-5 sec)
Inactive
Power On/O
Low Bottle Temp
History
Scroll Button
High Bottle Temp
History
Scroll Button
Cellar Pre-Chill
(Press and hold 3-5 sec)