WIRING
1. Install battery (note that battery is not included and must be Everstart #26 - 5
or equivalent) Obviously, use caution when hooking up battery.
2. Connect white wire from machine to brown wire of the recovery tank float
switch.
3. If equipped with an electric hose reel, run 10 Ga. Black wire from hose reel to
+ terminal on the starter. Use a 14 Ga. fusible link in between. Ground hose
reel to left front mount bolt of hose reel with existing ground wire terminal.
Note that machine recovery tank and hose reel must have common ground if
mounted to a wooden floor.
10