PULSE PUMP PRIMING
1. Assure chemical jug is adequately filled and the chemical input line is submersed
in chemical.
2. Open the CHEMICAL ADJUST valve (1 or 2 turns counterclockwise).
3. Set the CHEMICAL FEED switch to prime.
4. Start the machine and run at idle.
5. Flip the PUMP POWER switch to the “ON” position.
6. Allow water to flow until all the air is worked out of the chemical feed line and
flow meter.
7. Rotate the CHEMICAL FEED switch to the “ON” position. Chemical adjustment
can now be made as desired for the cleaning tool to be used.
CHEMICALS
Carpet Cleaning Chemicals: Always use a good quality emulsifier which is recommended for
use in truck-mounted equipment. Mix emulsifier thoroughly in accordance with the manufac-
turer’s recommendations. Note that combining two or more chemicals, inadequate dissolving
of powders, or using inferior quality materials may cause sedimentation and will clog the ma-
chine. Serious damage will result from using improper chemicals or mixtures.
Upholstery Cleaning Chemicals:
Use only chemicals recommended for wet cleaning of up-
holstery fabrics. Consult factory for specific instructions.
Pressure Washing Chemicals:
Use #1 or #2 pressure washing solvents only. Do Not Use the
highly aggressive #3 alkaline degreaser. Flush chemical system and pumping system with
clean water after job is complete.
24